Errors
Generator Parameters
Fan
Status
—%
Unknown
Phase Phasor Diagrams
Live voltage/current phasors per phase, straight from telemetry (amplitude + phase + frequency per AC channel) — no extra polling. The locked channel sits at north (0°); every other arrow and phase reading is shown relative to it. I/Q columns stay the raw (unrotated) ampl·cos/sin(phase).
Frequency / Amplitude / Phase / I-Q Trends
Tick any combination of phase + channel below to overlay them on the same charts and compare.
⚠ These are live control-loop gains, not device configuration.
Changing them takes effect immediately on the running PLL / amplitude / DC / current
control loops and can affect synchronization or stability. They are also
not persisted — a power cycle or a reset from the command
line while the knob is OFF reverts everything to firmware defaults.
Device Info
PLC
Power line communication link to connected ESO / EHUB devices — status, role, and detected devices.
Firmware Profiling
Internal diagnostics — CPU load and timing stats, not needed for normal servicing.
Device Limits
Safety-critical operating limits — read the warning below before changing anything.
⚠ Only change these if you know exactly what you are doing.
These are safety-critical operating limits — incorrect values can damage the device or create a
safety hazard. This is not necessary for normal operation or servicing.
Changes made here are persistent: they are saved to the device and survive power
loss and resets. Be very careful — a wrong value stays in effect until it is
changed back.
Measurement Overrides
Force measurement channels to fixed values for testing — bypasses the real sensor reading.
⚠ Overridden channels no longer reflect the real sensor value.
Safety logic (current limits, temperature cutoffs, phase checks, etc.) reads the overridden value too, not the
real one — so it can miss an actual fault, or trip on one that isn't really happening.
Overrides are not persisted: they clear on power cycle.
Bench Test Controls
Direct hardware control for bench testing — operation mode, PWM generator, relays, LED, and knob override.
⚠ These act directly on the hardware, bypassing the normal state machines.
A relay override or a manually driven PWM amplitude/offset stays in effect — fighting or
replacing whatever the app/worker/control-loop logic would otherwise do — until you clear
it, or the device loses power. Use with a scope or meter on the output, not with load
connected unless you mean to.
Operation Mode
Sinus PWM
Startup Ramp
ms
Relays
Relay
State
LED
Knob Override
Console
Raw serial CLI access — for debugging and commands not exposed elsewhere in the UI.